Showing 25–36 of 548 results

Lithium SuperPack 25,6V/50Ah (M8)

797.13 

The SuperPack batteries are extremely easy to install, not needing any additional components.
The internal switch will disconnect the battery in case of over discharge, over charge or high temperature.

The batteries can be connected in parallel. Series connection is not allowed.

 

Lithium SuperPack 12,8V/100Ah (M8)

621.25 

The SuperPack batteries are extremely easy to install, not needing any additional components.
The internal switch will disconnect the battery in case of over discharge, over charge or high temperature.

The batteries can be connected in parallel. Series connection is not allowed.

 

Lithium SuperPack 12,8V/200Ah (M8)

1,106.00 

The SuperPack batteries are extremely easy to install, not needing any additional components.
The internal switch will disconnect the battery in case of over discharge, over charge or high temperature.

The batteries can be connected in parallel. Series connection is not allowed.

 

Galvanic Isolator VDI-16 A

109.69 

The galvanic isolator prevents electrolytic corrosion. It blocks low voltage DC currents that enter your boat via the shore power earth wire. These currents can cause corrosion to the boat’s underwater metals, like the hull, propeller, shaft and so on.

Galvanic Isolator VDI-32 A

249.38 

The galvanic isolator prevents electrolytic corrosion. It blocks low voltage DC currents that enter your boat via the shore power earth wire. These currents can cause corrosion to the boat’s underwater metals, like the hull, propeller, shaft and so on.
The galvanic isolator consists internally of two diodes which are connected in anti-parallel fashion. When they are connected in this way, the diodes allow current in both directions but only above a certain threshold voltage. The voltage at which diodes conduct is about 1.4 Vdc.

The isolator is installed directly behind your boat’s 230V connection. The forward voltage from the galvanic isolator is higher than the potential difference between metals. As a result, this voltage will not allow conduction and as such, the galvanic isolator will prevent any electrolytic current. However, if there is a (higher) error voltage in the AC circuit, the diodes will allow current through and the residual-current device will break the circuit.

Galvanic Isolator VDI-64 A

305.63 

The galvanic isolator prevents electrolytic corrosion. It blocks low voltage DC currents that enter your boat via the shore power earth wire. These currents can cause corrosion to the boat’s underwater metals, like the hull, propeller, shaft and so on.
The galvanic isolator consists internally of two diodes which are connected in anti-parallel fashion. When they are connected in this way, the diodes allow current in both directions but only above a certain threshold voltage. The voltage at which diodes conduct is about 1.4 Vdc.

The isolator is installed directly behind your boat’s 230V connection. The forward voltage from the galvanic isolator is higher than the potential difference between metals. As a result, this voltage will not allow conduction and as such, the galvanic isolator will prevent any electrolytic current. However, if there is a (higher) error voltage in the AC circuit, the diodes will allow current through and the residual-current device will break the circuit.

Isolation Tr. 2000W 115/230V

397.50 

Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

Isolation Tr. 3600W 115/230V

598.13 

Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

Isolation Tr. 3600W Auto 115/230V

631.88 

Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

Isolation Tr. 7000W 230V

816.56 

Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

Autotransformer 120/240V-100A

509.06 

An Autotransformer can be used for step up, step down and split phase output balancing purposes.
While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.

Autotransformer 120/240V-32A

450.94 

An Autotransformer can be used for step up, step down and split phase output balancing purposes.
While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.